WCT modular contactor is applicable to alternative circuit with rated voltage up to 400V, rated current up to 100A and rated frequency 50/60Hz. The product is used for remote switching and controlling of power circuit.WCT contactor satisfies most application cases, such as household appliances, hotels, low inductance loading and household electromotor loading control for similar application.
Our WCT contactors can be combined with auxiliary control, protection and indication functions.The product is in conformity with IEC/EN 61095
Rated Current (A) | 16,20, 25, 40,63,100 |
Rated Voltage (V) | 230V 2P, 4P |
400V 4P | |
Rated Frequency(Hz) | 50/60Hz |
Electrical endurance | 30, 000 cycles |
Mechanical endurance | 100, 000 cycles |
Ambient temp. | pillar terminal with clamp |
Installation | On symmetrical DIN Rail |
Power circuit | |
Voltage rating (Ue)2P | 230/240VAC/24V |
Frequency | 50HZ or 60Hz |
Electrical | 100,000 cycles |
Maximum number of switching operation a day | 100 |
Additional characteristics | |
Insulation voltage Ui | 500VAC |
Pollution degree | 2 |
Rated impulse withstand voltage (Uimp) | 2.5kv(4kv for 12/24/48VAC ) |
Degree of protection device only | IP20 |
IEC60529 Device in modular enclosure | IP40 |
Operating temperature | -5 to 60 degree |
Storage temperature | -40~70degree |
Tropicalization (IEC60068-1) | Treatment 2 (relative humidity 95% at 55 degree ) |
ELSV compliance (extra low safety voltage )for 12/24/48vac versions | |
The products control confirms to the selv(safety extra low voltage )requirements |
Power circuit | ||
Voltage Rating(Ue) 1P, 2P | 250V AC | |
3P, 4P | 400V AC | |
Endurance(O-C) | ||
Electrical | 100,000 cycles | |
Maximum number of switching operation each day | 100 | |
Additional characteristics | ||
Insulation voltage(Ui) | 500V AC | |
Pollution degree | 2 | |
Rated impulse withstand voltage(Uimp) | 2.5kV(4KV for 12/24/48V AC) | |
Degree of protection | Device only | IP20 |
Device in modular | IP40 | |
Operating temperature | -5℃ to +60℃ | |
Storage temperature | -40℃ to +70℃ | |
Tropicalization (IEC 60068-1) | Treatment 2(relative humidity 95% at 55℃)
|
Specification
Standard control voltage (Ue):20-230V/50/60Hz
Thermal continuous current (1th):24A
Current rating for AC1:24A
Pole number: 2, 4(either as main or auxiliary contacts)
Back up fuse gl max ratings: 35, 63,80A
Mechanical endurance: 10 million cycles
Electrical endurance: 1 million cycles
Ambient temperature: -25~+55 degree Celsius
Connection capacity: tunnel terminal for cables up to 25 square millimeters
Width in 17.5 square millimeters modules: 24A 35 millimeters (2 modules)